Vacuum Networks

Description

Local-Area Vacuum Network VACUU·LAN® - a modular concept

A single vacuum pump for several users!

... space-saving, economic and easily expandable

Application

Vacuum generation for several applications such as rotary evaporators, drying cabinets or filtrations with a single vacuum pump.

Advantages

  • space-saving, economic and flexible
  • modular system, expandable or adjustable at any time
  • process oriented connections according to the demands at the work place:
      • choice of manual stainless steel isolation valve (ball valve)
    • or manual fine tuning of pumping speed with flow control valve
    • or automatic vacuum control with vacuum controller and solenoid valve
    • optional additional fine tuning of pumping speed with flow control valve
    • optional additional vacuum level indication
  • non-return valves against cross interference
  • practical assembling due to connection with individually adaptable PTFE-tubing
  • connection to covered tubing in ducts or to open tubing (e.g., refurbishment) 
  • retrofitting of existing laboratory equipment also easily possible

 

VACUU·LAN®-Modules VCL

The VCL modules are completely assembled, individually tested and ready to be connected in newly planned laboratory furniture or for installation into existing laboratories (e.g. refurbishment with wall-mounted units).

Technical data

Step 1: Choice of the appropriate connecting part

The connecting parts are the link between the vacuum network tubing and the VACUU·LAN® operating modules (see Step 2). The main criterion for the choice of the appropriate connecting part A1 or A5 is whether VACUU·LAN® is planned for a new laboratory or for upgrading an existing laboratory or vacuum network.

Connecting part A1
For surface mounting of the vacuum lines. The most common solution for the installation of a VACUU·LAN® network onto existing laboratory furniture or on walls (e.g. refurbishment) .

Connecting part A5
For integration of the vacuum network into the furniture. The PTFE vacuum tubings run hidden below the surface. Connections are mounted from the front.

Special connecting parts only for upgrading of existing older vacuum networks are available also. More information on request.

Step 2: Choice of the appropriate VACUU·LAN® operating modules

Manual flow control module VCL 01
With manual flow control to open / close the vacuum line and to control the flow rate.

Shut-off / manual flow control module VCL 02
For manual control of flow rate, combined with a ball valve for quick opening / closing of the vacuum line. The flow rate setting is maintained.

Manual flow control / shut-off / gauge module VCL RKM
Similar to module VCL 02, but with additional mechanical bourdon vacuum gauge to monitor the vacuum.

Automatic control module VCL-B 10
Electromagnetic (solenoid) valve. Allows automatic vacuum control in combination with vacuum controller VNC 2 or CVC 3000.

Manual flow control / automatic control module VCL-B 11
Electromagnetic (solenoid) valve for automatic vacuum control with additional manual flow rate control.

Shut-off module VCL K
With ball valve for quick opening / closing of the vacuum line.

Manual flow control module for hoods VCL AR
Consists of a manual control unit for installation outside the hood, and a separate vacuum port for installation inside the hood.

Automatic control module for hoods VCL-B AE
Consists of an automatic control unit for installation outside the hood, and a separate vacuum port for installation inside the hood. Additional measuring port inside the hood for connection of vacuum controller VNC 2 or CVC 3000.

Order data

Local vacuum network VACUU•LAN®

Cat. No.

With connecting part A1
(for wall mounting)
 
Manual flow control module VCL 01 A1 67 71 06
Shut-off / manual flow control module VCL 02 A1 67 71 07
Automatic control module VCL-B 10 A1 67 72 08
Automatic control / manual flow control module VCL-B 11 A1 67 72 09
Shut-off module VCL K A1 67 71 55
Shut-off/gauge module / manual flow control module VCL RKM A1 67 71 75
With connecting part A5  
Manual flow control module VCL 01 A5 67 71 90
Shut-off / manual flow control module VCL 02 A5 67 71 91
Automatic control module VCL-B 10 A5 67 72 92
Automatic control / manual flow control module VCL-B 11 A5 67 72 93
Shut-off module VCL K A5 67 71 94
Manual flow control module for hoods VCL AR A5 67 71 95
Automatic control module for hoods VCL-B AE A5 67 72 96
Shut-off/gauge module / manual flow control module VCL RKM A5 67 71 97