DVR 3proVacuum gauge

Overview

  • Flexible application range due to mains-independent operation of the fully electronic vacuum gauge with ATEX approval
  • Large, graphical analog display combined with precise digital readout allows users to detect and view tendencies easily
  • Improved functionality within the navigation menu helps to save energy and to increase the life cycle of the battery; battery easily replaceable; no lithium battery
  • High reliability, low EMI emission level near detection limit, high degree of immunity to electromagnetic interference, suitable for use in industrial environments
  • Capacitive ceramic diaphragm vacuum sensor made of aluminum oxide with excellent chemical resistance, accuracy and long-term stability
Articleno. 20682907
On demand

Inquire

Vacuum gauge in action

The DVR 3pro is a fully electronic, versatile vacuum gauge with ATEX approval for use in areas with potentially explosive atmospheres (ATEX category 2). Thanks to the easy operation and the combined digital/analog pressure display, measured values can be viewed fast and precisely. The DVR 3pro has an integrated pressure sensor made of aluminum oxide ceramic with excellent corrosion resistance and high long-term stability. A particular advantage is the flexible use with 9V battery power supply (mains-independent operation). Approved batteries are available from retail outlets. The removable cover at the back of the gauge allows for easy battery replacement. (Note: battery replacement must be done outside the hazardous ATEX area.)


Information on the disposal of old devices »

Technical data and graphs

Upper measuring limit in mbar/hPa 1060 mbar
Upper measuring limit in torr 795 torr
Lower measuring limit in mbar/hPa 1
Lower measuring limit in torr 1 torr
Measurement principle Ceramic diaphragm (alumina), capacitive, gas indep., absolute pressure
Accuracy of measurement < +- 1 mbar/hPa/torr / +- 1 digit (after adjustment, constant temp.) mbar/hPa/torr
ATEX conformity II 2G EX ib IIC T4 Gb
Temperature coefficient < 0.15 mbar/hPa/0.11 torr /K mbar/hPa/torr /K
Vacum connection Small flange KF DN 16, PTFE tubing connection 10/8 mm, hose nozzle DN 6/10 mm
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Max. media temperature for continuous operation 40 °C
Max. media temperature short term 80 °C
Automatic switch-off User-selectable: 1-600 min (default 5 min) or continuous operation min
Measurement cycle User-selectable: Automatic or 1 x per 3s, 1 x per 1s, 3 x per 1s
Material of outer housing Robust plastic housing with good chemical resistance
Protection class IEC 60529 IP 40
Power supply 9 V battery
Weight 0.4 kg
Dimension L in mm 117 mm
Dimension B in mm 117 mm
Dimension H in mm 91 mm
Vacuum sensor Integr.
Typical battery lifetime 4.000 h, stand-by: 30.000 h h
NRTL certification No
Items supplied Vacuum gauge complete with integrated vacuum sensor, including battery, hex key, connecting parts and manual.

Equipment

This might also interest you

Vacuum gauge in action

The DVR 3pro is a fully electronic, versatile vacuum gauge with ATEX approval for use in areas with potentially explosive atmospheres (ATEX category 2). Thanks to the easy operation and the combined digital/analog pressure display, measured values can be viewed fast and precisely. The DVR 3pro has an integrated pressure sensor made of aluminum oxide ceramic with excellent corrosion resistance and high long-term stability. A particular advantage is the flexible use with 9V battery power supply (mains-independent operation). Approved batteries are available from retail outlets. The removable cover at the back of the gauge allows for easy battery replacement. (Note: battery replacement must be done outside the hazardous ATEX area.)


Information on the disposal of old devices »

Technical data and graphs

Upper measuring limit in mbar/hPa 1060 mbar
Upper measuring limit in torr 795 torr
Lower measuring limit in mbar/hPa 1
Lower measuring limit in torr 1 torr
Measurement principle Ceramic diaphragm (alumina), capacitive, gas indep., absolute pressure
Accuracy of measurement < +- 1 mbar/hPa/torr / +- 1 digit (after adjustment, constant temp.) mbar/hPa/torr
ATEX conformity II 2G EX ib IIC T4 Gb
Temperature coefficient < 0.15 mbar/hPa/0.11 torr /K mbar/hPa/torr /K
Vacum connection Small flange KF DN 16, PTFE tubing connection 10/8 mm, hose nozzle DN 6/10 mm
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Max. media temperature for continuous operation 40 °C
Max. media temperature short term 80 °C
Automatic switch-off User-selectable: 1-600 min (default 5 min) or continuous operation min
Measurement cycle User-selectable: Automatic or 1 x per 3s, 1 x per 1s, 3 x per 1s
Material of outer housing Robust plastic housing with good chemical resistance
Protection class IEC 60529 IP 40
Power supply 9 V battery
Weight 0.4 kg
Dimension L in mm 117 mm
Dimension B in mm 117 mm
Dimension H in mm 91 mm
Vacuum sensor Integr.
Typical battery lifetime 4.000 h, stand-by: 30.000 h h
NRTL certification No
Items supplied Vacuum gauge complete with integrated vacuum sensor, including battery, hex key, connecting parts and manual.

Equipment

This might also interest you