Set DCP 3000 + VSK 3000Vacuum gauge

Overview

  • vacuum measuring device for connecting external vacuum sensors for measurements directly on the system
  • flexible and expandable with up to eight sensors, four of the types VSK 3000 / VACUU·VIEW (Atm. to 0.1 mbar) and VSP 3000 / VACUU·VIEW extended (Atm. up to 10-3 mbar)
  • relative pressure measurement with reference sensors (VSK 3000) and data logger function with up to 32000 measuring points (RS 232C)
  • capacitive ceramic diaphragm vacuum sensor VSK 3000 made of aluminum oxide with high chemical resistance, gas type independent absolute pressure measurement
  • excellent measurement accuracy, temperature and long-term stability
Articleno. 20683170
On demand

Inquire

Vacuum gauge in action

The fully electronic vacuum measuring device DCP 3000 is both versatile and decisive with its mechanical robustness, measuring accuracy and reliability. The large, illuminated display provides the measured value display of all connected sensors via an easy-to-use rotary control. Up to eight vacuum sensors (four of each type VSK 3000 / VACUU·VIEW and VSP 3000 / VACUU·VIEW extended) can be connected to the DCP 3000. The measurement can be carried out directly on the application. The DCP 3000 enables a relative pressure measurement (reference sensor VSK 3000) as well as working with pressure-dependent switching points by specifying switch-on and switch-off points on an external valve. The vacuum measuring device can also be used as a data logger with up to 32,000 measuring points. The data is read out via the serial interface (RS 232C). The ceramic membrane vacuum sensor VSK 3000 is suitable for the measuring range from atmospheric pressure to 0.1 mbar. It measures regardless of the gas type and is highly chemically resistant, which means that the measurement can be carried out directly at the process, with excellent measurement accuracy and high long-term and temperature stability. Please also note our alternative product VACUU·VIEW.


Information on the disposal of old devices »

Technical data and graphs

Upper measuring limit in mbar/hPa 1080 mbar
Upper measuring limit in torr 810 torr
Lower measuring limit in mbar/hPa 0.1
Lower measuring limit in torr 0.1 torr
Measurement principle Ceramic diaphragm (alumina), capacitive, gas indep., absolute pressure
Accuracy of measurement < +- 1 mbar/hPa/torr / +- 1 digit (after adjustment, constant temp.) mbar/hPa/torr
ATEX conformity II 3/- G Ex h IIC T3 Gc X Internal Atm. only
Temperature coefficient < 0.07 mbar/hPa/0.05 torr /K mbar/hPa/torr /K
Vacum connection Small flange KF DN 16, PTFE tubing connection 10/8 mm, hose nozzle DN 6/10 mm
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Max. media temperature for continuous operation 40 °C
Max. media temperature short term 80 °C
Material of outer housing Robust plastic housing with good chemical resistance
Protection class IEC 60529 IP 20
Protection class UL50E Type 1
Protection class front side IEC 60529 IP 42
Weight 0.44 kg
Dimension L in mm 144 mm
Dimension B in mm 124 mm
Dimension H in mm 114 mm
Vacuum sensor VSK 3000
Cable length of vacuum sensor 2 m
Cable length connection in m 2 m
NRTL certification Yes
Items supplied Vacuum gauge with external vacuum sensor VSK 3000, ready for operation, with kit hose nozzle DN 6/10 mm, wall-plug power supply and manual.
Interface RS 232C

Equipment

This might also interest you

Vacuum gauge in action

The fully electronic vacuum measuring device DCP 3000 is both versatile and decisive with its mechanical robustness, measuring accuracy and reliability. The large, illuminated display provides the measured value display of all connected sensors via an easy-to-use rotary control. Up to eight vacuum sensors (four of each type VSK 3000 / VACUU·VIEW and VSP 3000 / VACUU·VIEW extended) can be connected to the DCP 3000. The measurement can be carried out directly on the application. The DCP 3000 enables a relative pressure measurement (reference sensor VSK 3000) as well as working with pressure-dependent switching points by specifying switch-on and switch-off points on an external valve. The vacuum measuring device can also be used as a data logger with up to 32,000 measuring points. The data is read out via the serial interface (RS 232C). The ceramic membrane vacuum sensor VSK 3000 is suitable for the measuring range from atmospheric pressure to 0.1 mbar. It measures regardless of the gas type and is highly chemically resistant, which means that the measurement can be carried out directly at the process, with excellent measurement accuracy and high long-term and temperature stability. Please also note our alternative product VACUU·VIEW.


Information on the disposal of old devices »

Technical data and graphs

Upper measuring limit in mbar/hPa 1080 mbar
Upper measuring limit in torr 810 torr
Lower measuring limit in mbar/hPa 0.1
Lower measuring limit in torr 0.1 torr
Measurement principle Ceramic diaphragm (alumina), capacitive, gas indep., absolute pressure
Accuracy of measurement < +- 1 mbar/hPa/torr / +- 1 digit (after adjustment, constant temp.) mbar/hPa/torr
ATEX conformity II 3/- G Ex h IIC T3 Gc X Internal Atm. only
Temperature coefficient < 0.07 mbar/hPa/0.05 torr /K mbar/hPa/torr /K
Vacum connection Small flange KF DN 16, PTFE tubing connection 10/8 mm, hose nozzle DN 6/10 mm
Lower ambient temperature (storage) -10 °C
Upper ambient temperature (storage) 60 °C
Lower ambient temperature (operation) 10 °C
Upper ambient temperature (operation) 40 °C
Max. media temperature for continuous operation 40 °C
Max. media temperature short term 80 °C
Material of outer housing Robust plastic housing with good chemical resistance
Protection class IEC 60529 IP 20
Protection class UL50E Type 1
Protection class front side IEC 60529 IP 42
Weight 0.44 kg
Dimension L in mm 144 mm
Dimension B in mm 124 mm
Dimension H in mm 114 mm
Vacuum sensor VSK 3000
Cable length of vacuum sensor 2 m
Cable length connection in m 2 m
NRTL certification Yes
Items supplied Vacuum gauge with external vacuum sensor VSK 3000, ready for operation, with kit hose nozzle DN 6/10 mm, wall-plug power supply and manual.
Interface RS 232C

Equipment

This might also interest you